Now under USB device: you will be able to see all recognized connected devices. Provides support for Ethernet, GPIB, serial, USB, and other types of instruments. A valid service agreement may be required. rj-45 以太网端口2 National Instruments cRIO-9082 Reconfigurable Embedded Chassis w/ Integrated Intelligent RealTime Controller for CompactRIO. Installing the cRIO-9012/9014 in the Chassis 1 4 3 2 1. Integrated CompactRIO Real-Time Controller: cRIO-9081, cRIO-9082, cRIO-906x, and cRIO-903x; Single-Board RIO: sbRIO-9627, sbRIO-9607; CompactRIO Real-Time Controller: cRIO-9032, cRIO-9037;. Provides support for Ethernet, GPIB, serial, USB, and other types of instruments. Figure 3. For more information, please see the Phar Lap RT OS EOL Road Map. 118. If anyone already has such a program and is willing to share, it would be greatly appreciated. Provides support for Ethernet, GPIB, serial, USB, and other types of instruments. You can access the file by connecting to. ni gpibコントローラおよびgpibポートを備えたni組込コントローラをサポートします。ni-daqmx. If there is any unselected item, check the box and select Next to install it. When compiling our (largish) project I almost always get a timing violation during compilation on this loop (I think 1 out 15 times it worked). For information about software for CAN products from other vendors, refer to. Having said that I want to tak. Ho provato anche a non configurare nessun indirizzo. Added support for NI cRIO-9081/9082; The CANopen VIs palette includes the following changed polymorphic VI instance: CANopen Interface Create—Includes an optional termination? input that enables or disables the onboard termination. 60 GHz Quad-Core CPU, 4 GB DRAM, 16 GB Storage, Kintex-7 325T FPGA, 8-Slot CompactRIO Controller Definitions Warranted specifications describe the performance of a model under stated operatingIn this study, the vehicle drivetrain, three fuel cells, and a lithium-ion battery are simulated in the RT controller of the NI cRIO 9082, and the FPGA module controls and monitors a 500 W fuel. Provides support for NI data acquisition and signal conditioning devices. Controller 2. On the cRIO-9075 with Labview RT 13. 2. Click Set Permission button to open the NI Web-based Configuration and Monitoring. rack rack mounting cRIO-9081 cRIO-9082 DIN DIN rail 19 19-in. ni gpibコントローラおよびgpibポートを備えたni組込コントローラをサポートします。 Open a service request. NI-488. dll files , in the same way you can execute them in Windows. I have a project containing cRIO 9082 with a EtherCAT master connected to a NI 9144. . Member. To restore my Linux x64-based CompactRIO (cRIO), sbRIO, PXI Real-Time controller, stand-alone USRP controller, or other real-time targets to factory. The performance of the proposed algorithm is verified and demonstrated for the different tests mentioned in synchrophasor standard IEEE C37. Using PROFIBUS Module as a Master#engineeringencyclopedia----- : ) -----Thanks For Watching Don't Forgot to "SUBSCRIBE"Any queries please drop it down in comment Boxtext u. 소프트웨어 다운로드. High-Performance Test. Open a service request. The cRIO-9082 filters and regulates the supplied power and provides power for the C Series modules. CompactRIO . cRIO-9082. Follow the instruction below : Open the NI MAX, find the cRIO controller under Remote Systems. built into the product if the product is damaged in any way. 3) In the IP-adress, type the IP-adress you see in the network browser. Distributed Measurement and Control. However, two errors are occurring: 1). The shock and vibration. Systems Engineering Software. NI cRIO-9082 지능형 리얼타임 컨트롤러가 통합된 CompactRIO용 재구성가능한 임 베디드 섀시 이 문서는 NI cRIO-9082의 스펙이 정리된 문서입니다. 0. Provides support for NI GPIB controllers and NI embedded controllers with GPIB ports. ni-daqmx. 分散 計測/ 制御. 2. A NI cRIO-9082 controller, an NI 9159 MXI-Express RIO chassis, a NI USB-8451 interface, a NI 9227 C Series module, NI 9225 C Series modules, and NI 9485 modules increase the reliability, run time, and life span of the battery pack in the BMS. I am implementing I2C protocol using NI9401 on Ni cRIO FPGA to read a smart battery data. 0. Perspectives. NI GPIBコントローラおよびGPIBポートを備えたNI組込コントローラをサポートします。cRIO-9081* cRIO-9082*. To connect it, remove analog input jumpers. 0: N/A: 1. Currently, I am able to see the cRIO under 'Remote Devices' in MAX and view configurations. ethernet、gpib、シリアル、usbおよびその他のタイプの計測器をサポートします。 ni-488. The cRIO-9082 has a primary power input, V1, and a secondary power input,. Open a service request. 分散 計測/ 制御. From troubleshooting technical issues and product recommendations, to quotes and orders, we’re here to help. CompactRIOターゲット上でスキャンインタフェースとLabVIEW FPGAインタフェースを同時に使用する方法は、ハイブリッドモードと呼ばれています。. National Instruments cRIO-9082 Reconfigurable Embedded Chassis w/ Integrated Intelligent RealTime Controller for CompactRIO. That's for the version with Windows 7 Embedded installed. 2. In this study, the vehicle drivetrain, three fuel cells, and a lithium-ion battery are simulated in the RT controller of the NI cRIO 9082, and the FPGA module controls and monitors a 500 W fuel. led 指示灯 2. 2. The CompactRIO chassis is the center of the integrated system architecture. Provides support for Ethernet, GPIB, serial, USB, and other types of instruments. 1 installed NI-VISA Server 5. NI-VISA. In order to program your cRIO you need to have the following software installed on your computer in this order: LabVIEW Development System. 2. We integrated the simulator in a verification model, together with protection and conditioning components as well as the lift’s maneuver, to be analyzed. Provides support for NI data acquisition and signal conditioning devices. Provides support for NI GPIB controllers and. This page is part of the CompactRIO System Accessory Compatibility Guide. 0 Host Port RJ-45 Gigabit Ethernet Port 1 2 GB DDR3 32 GB CFast SSD RS. 781989-01 cDAQ-9138 cDAQ-9139In this study, the vehicle drivetrain, three fuel cells, and a lithium-ion battery are simulated in the RT controller of the NI cRIO 9082, and the FPGA module controls and monitors a 500 W fuel. Systems Engineering Software. Provides support for NI GPIB controllers and NI embedded controllers with GPIB ports. This project is being handled by IIT P. Safety Guidelines for Hazardous Locations. In addition, MATLAB can communicate with the serial port RS-232 port on the controllers. Safety Guidelines. Provides support for NI data acquisition and signal conditioning devices. Ni crio-9035 user manualNi crio-9048 8-slot embedded compactrio controller (tsn supported Ni crio-9067 getting started manual pdf downloadNi crio-9058 manuals. Study ResourcesThis page documents all the applicable standards and certifications for the cRIO-9082 and provides downloadable certifications. To. Perspectives showcases how NI sees what’s next in the world of test and technology. 2. You can compromise the safety protection. Ethernet、GPIB、シリアル、USBおよびその他のタイプの計測器をサポートします。 NI-488. NI-VISA. NI-VISA. Are there any tricks or third party solutions that could get us to 2. " are. For example : I have cRIO 9205 & 9264 modules in my chassis. Options. Ethernet connection between NI-cRIO 9082 and Amanda’s computer established. The cRIO-9082 is an embedded controller ideal for advanced control and monitoring applications. I would know how to realize my FPGA software development. NI cRIO-9081 1. 1 started successfully. 0. lvlibp:myProgram. Good morning, I would like to know DMA bandwidth of cRIO-9082 between FPGA and RT? How many MB/s? I can not find answer on NI web page. This document describes how to begin using the National Instruments cRIO-9082. Using this CompactRIO System Accessory Guide. Provides support for Ethernet, GPIB, serial, USB, and other types of instruments. Software : VeriStand 2012 f2. Figure 7 shows the connection diagram of the developed BMS. In a CompactDAQ system, a chassis is connected to your PC through USB or Ethernet, and then populated with one or more conditioned I/O modules for direct sensor connectivity. I assume you are running the RT OS. ni-daqmx. Solution. Reconfigurable Embedded Chassis 3. Hi, I need to use a NI cRIO 9082RT chassis with cRIO modules. For example, if you are using the cRIO-9081, there is a section titled Installing an Operating System in the user manual, which outlines the steps. What is the issue that's happening to cRIO-9082? NI doesn't provide cRIO9082 schematic because it is a confidential document. Systems Engineering Software. Once NI-CAN is installed on the development machine, it must also be installed onto the CompactRIO from Measurement & Automation Explorer (MAX). I switched the IP Reset to On, rebooted and switched IP Reset to off. This rugged, fanless controller features a variety of connectivity ports, including one Ethernet and one serial. Distributed Measurement and Control. RS-232 Serial Port 3. NI R 시리즈 다기능 RIO 디바이스 드라이버. Knight of NI. If your main goal is HIL simulation rather than RCP, the PXIe FlexRIO PXIe-7966R is recommended. The Intel Atom SoC delivers a massive amount of performance and functionality, including an integrated GPU and a multicore processor. Software. dip 开关 8. The following document describes the process for remote development, debugging and deployment of an application intended to run on the Windows Embedded Standard 7 (WES7) operating system on a CompactRIO, specifically the cRIO 9081 or the cRIO 9082. Once NI-CAN is installed on the development machine, it must also be installed onto the CompactRIO from Measurement & Automation Explorer (MAX). Both system runs FPGA code. The software includes LabVIEW, the LabVIEW FPGA Module, the LabVIEW Real-Time Module, and NI-RIO. 産業用機械. 33GHz, 2Cores, 2GB, 8Slots. OSGP13 National Instruments NI cRIO-9082 151712E-02L Bios Version 1. Provides support for NI GPIB controllers and. The hardware includes PC, the NI PXI controller, and CompactRIO. LabVIEW Real-Time 모듈. I didn't noticed that you are using a cRIO with Windows. NI GPIBコントローラおよびGPIBポートを備えたNI組込コントローラをサ. Ok, let's see. Industries. 2. 0 host port (NI USB Extender Cable, 152166-xx), USB type-C ports (NI Locking USB Cables, 143556-xx; NI USB. Thanks!ni-daqmx. I recommend you contact NI for RMA instructions. Getting Started Guide Installing Software on the Host Computer Before using the cRIO-9082, you must install the following application software and device drivers on the host computer in this order: 1. Re: NI 9401 + cRIO 9082 speed measurement. User Accessible/ Battery . NI-VISA. 10-04-2017 04:45 PM. Model Number(s): NI CRIO-9082 Part / Assembly Number(s): 151712E-14L (rev E or higher) National Instruments declares that, to its knowledge as of the date of this document, the products listed above conform to the requirements of the European Union’s Restriction of the Use of Certain Hazardous Substances (RoHS) Directive 2002/95/EC. 分散 計測/ 制御. Academic and Research;. Slide the controller onto the controller slot on the chassis. Aerospace, Defense, & Government. [ FPGA | RT | DSC | Robotics ]Hi, We already have a cRIO 9082 and REALLY want to generate a 25 MHz (manchester) signal with it (in order to sync with another device that needs the 25 MHz manchester). Hi, I'm hoping for help on a timing violation. Software. Distributed Measurement and Control. I'm fairly new to Labview and just happen to research about Modbus on a basic level, which I understand simple data allocation and message framing. 2. It features an FPGA and a processor running either a real-time OS or Windows Embedded Standard 7 (WES7). Newark offers fast quotes, same day shipping, fast delivery, wide. In NI-MAX click the Login button on the toolbar after you have selected your target, and enter the username and password. The cRIO-9082 provides a chassis grounding screw. Connecting the cRIO-9082 to the Host Computer or Network Using Ethernet This document lists the specifications for the National Instruments cRIO-9038. I can`t switch between states. Systems Engineering Software. CompactRIO . cRIO-9081/9082 Firmware and Additional Drivers. CompactRIO cRIO-9012/9014 1 8 3 5 7 4 6 2 1. I need to quickly write a simple VI that acquires analog input data from a cRIO-9082 using NI-9205 and NI-9213 modules to acquire pressure and temperature measurements. 10. are not included with this equipment unless listed in the above stock item description. Provides support for NI data acquisition and signal conditioning devices. Ferite rings are to prevent electromagnetic interference from the power cable getting into to other devices. I am trying to create a VI to output a digital signal to a relay from the NI 9472. NI cRIO 9082 manufactured by National Instruments is used as an FPGA platform for carrying out the experiment in this work. USB 2. This guide includes the cRIO-901x, cRIO-902x, cRIO-903x, cRIO-904x, cRIO-906x, cRIO-907x, cRIO-908x. From troubleshooting technical issues and product recommendations, to quotes and orders, we’re here to help. 分散 計測/ 制御. 0. CompactRIO . Provides support for Ethernet, GPIB, serial, USB, and other types of instruments. Distributed Measurement and Control. Every time I compile there is less space on the 32 storage card . Compatible. I followed the steps for creating a webserver using this NI link. The new NI Distributed System Manager helps you get up and running quickly by adding test panels to CompactRIO. In case you are connecting your cRIO to a Network, make sure both computers are set to get an IP address from the DHCP server. 05-31-2013 10:38 AM. Se vado. This page documents all the applicable standards and certifications for the cRIO-9082 and provides downloadable certifications. NI GPIBコントローラおよびGPIBポートを備えたNI組込コントローラをサポートします。CompactRIO . Part Number: 151712D-12L, 151712H. Perspectives. NI-DAQmx. Provides support for NI data acquisition and signal conditioning devices. これにより、いくつかのモジュールがFPGAを使用している間. A NI cRIO-9082 controller, an NI 9159 MXI-Express RIO chassis, a NI USB-8451 interface, a NI 9227 C Series module, NI 9225 C Series modules, and NI 9485 modules increase the reliability, run time, and life span of the battery pack in the BMS. Currently I am working on a internship project. Figure 7 shows the connection diagram of the developed BMS. NI CompactRIO 20. cRIO-9002. Provides support for NI data acquisition and signal conditioning devices. dll not found! (dependency) SoftMotion Module initialized. . Options. Provides support for NI GPIB controllers and. number, such as NI-cRIO-9082-1856AAA. NI Part Number: 375898A-01 Board Model Name Board Part Number Range 908x Series cRIO 151712A-01L, 151712A-02L Manufacturer: National Instruments Volatile Memory. Provides support for NI GPIB controllers and. NI CompactRIO Device Drivers Media 4. This document also contains specifications for the cRIO-9081/9082. . The following specifications are typical for the -40 °C to 70 °C operating temperature range unless otherwise noted. Update with NI MAX: Open NI MAX. Hi, now i am using CRIO 9082 for RT testing (vehicle simulator in hard Real TIme) but, while developing the platform, chassis CAN module C9862 can not be worked. Provides support for Ethernet, GPIB, serial, USB, and other types of instruments. NIの集録および信号調整デバイスをサポートします。 NI-VISA. Hi, I'm hoping for help on a timing violation. Provides support for NI data acquisition and signal conditioning devices. Matt J | National Instruments | CLA 0 Kudos Message 2 of 8 (2,891 Views) Reply. Provides support for NI data acquisition and signal conditioning devices. niの集録および信号調整デバイスをサポートします。 ni-visa. With the release of the Multicore CompactRIO systems, the cRIO-9081 and cRIO-9082, National Instruments now offers a choice of either a real-time or a Windows Embedded Standard 7 (WES7) operating system. USB Host Port 5. Ni crio-9048National instruments ni crio-9036 user manual pdf download Ni crio-9047Pac crio controller. 03-04-2016 10:47 AM. Software. Provides support for NI GPIB controllers and NI embedded controllers with GPIB ports. Distributed Measurement and Control. NI Linux. Provides support for Ethernet, GPIB, serial, USB, and other types of instruments. NI-488. com | NI cRIO-9082 Specifications This document describes how to connect the NI cRIO-9081/9082 integrated controller and chassis to a network and how to use the features of the cRIO-9081/9082. In addition, MATLAB can communicate with the serial port RS-232 port on. Rob B. Available. rs-232 串口 4. If you still can't see your device it would be a good idea to call NI's support engineering department (000 817 947 8791). I have a cRIO 9082 with labview 2019 (RT and FPGA). 8 -20 ºC to 55 ºC cRIO-9063 667 MHz Dual-Core ARM Cortex-A9 Zynq-7000 (Z-7020) 512 MB 256 MB 4 -20 ºC to 55 ºC cRIO-9064 667 MHz Dual-Core ARM Cortex-A9 Zynq-7000 (Z-7020) 1 GB 512 MB 4 -20 ºC to 55 ºC Options. ** NI will remove support for Phar Lap for cRIO in the NI 2020 Software Release and for PXI in the NI 2022 Software Release. ni crio-9022 compactrio 智能实时嵌入式控制器 本文档主要介绍ni crio-9022 的安装、使用方法以及产品规范。 图 1. It features an FPGA and a processor running either a real-time OS or Windows Embedded Standard 7 (WES7). NI-VISA. The Automotive Diagnostic Command Set 14. The following instructions are for host computers running Windows 7. Software. Hi I need to connect a usb device and read in serial mode. Hello, I'm using the cRIO 9082 with Windows. Provides support for Ethernet, GPIB, serial, USB, and other types of instruments. Perspectives. ni-daqmx. The NI cRIO 9082 has an internal real-time clock as well, which offers 200 ppm accuracy. cRIO Device with Power Connector 2. rtexe and startup. Provides support for NI GPIB controllers and NI embedded controllers with GPIB ports. Can any body tell me that I can interface Matlab with this specific RIO system and access all the ports from Matlab/Simulink? NI claims the interface should be similar to their CompactDAQ devices, and not similar to the (older) cRIO devices. The NI cRIO-9082 has Free Ground Shipping and a 1-3 Year Warranty, depending on New, Reconditioned, Used, or Repair Status. Note Some C Series modules have additional power requirements. 31 mm (16 AWG) solid copper wire with a maximum length of 1. National Instruments 783832-01 Dual Core Controller with ZYNQ-7020 FPGA and Extended Temperature. 5: NI-9146 NI-9148 NI-9157 NI-9159 cRIO-9075 cRIO-9076 PCIe-1473R sbRIO-9605 sbRIO-9606 sbRIO-9623 sbRIO-9626 sbRIO-9633 sbRIO-9636: ISE 10. Product misuse can result in a hazard. Note: The exception exists when this is the desired state for shared helper code that, for. Distributed Measurement and Control. I have installed Labview Professional 2011 on my host computer (default Installation) and configured my cRIO in MAX. Each channel provides access to an electromechanical relay for switching signals up to 60 VDC (1 A) or 250 Vrms (1. In the BIOS Advanced tab select USB Configuration and press Enter. NI-488. 0 and later, you can disable Safe Mode by modifying the ni-rt. . Re: FPGA loop time optimization - CRIO 9082 - 9224 analog input module JFBerlemont. Page 17: Chassis Grounding Screw. The monitor ports for 9082 is there for 2 reasons. cRIO-908x Firmware and Additional Drivers provides support for compatible CompactRIO Controllers. High-Performance Test. 5 m (5 ft). NI-DAQmx. Software. Provides support for Ethernet, GPIB, serial, USB, and other types of instruments. This update is strongly recommended for LabVIEW Real-Time Module users with RT PXI, cRIO-9081/9082,. Resources. Provides support for Ethernet, GPIB, serial, USB, and other types of instruments. 1 (non-Virtex II targets)2:NI cRIO-9012/9014 Intelligent Real-Time Embedded Controllers for CompactRIO Figure 1. This rugged, fanless. 高性能 テスト. PXI. NI-VISA. crossrulz. Distributed Measurement and Control. Finding the cRIO-9082 on the Network (Static IP) Complete the following steps to find the cRIO-9082 on the network if the host computer is using a static IP address. Distributed Measurement and Control. 31 mm (16 AWG) solid copper wire with a maximum length of 1. Website. Hi everyone, I've been trying to set up a new cRIO the NI-9082. 2. . From troubleshooting technical issues and product recommendations, to quotes and orders, we’re here to help. Voltage input range (measured at the cRIO-9082 power connector) V1 9 V to 30 V V2 9 V to 30 V Maximum power consumption 75 W 4 | ni. Go to NI Package Manager. NI CompactRIO 20. . Try to do the following: 1) Right click on 'Remote Systems' and select 'Create New'. From troubleshooting technical issues and product recommendations, to quotes and orders, we’re here to help. 168. Hello all. To do this, you need to turn off your cRIO, go to the DIP switches on your cRIO and get the "safe mode" switch on the ON position. It shouldn't make any difference to the cRIO, but they may help if you are using a IO module that is sensitive to electromagnetic interference - which depends on module. opkg install dotnet-sdk opkg install fsharp. I can't really find any detailed compatibility information in the white pages, at least nothing that suggest I can't upgrade. Figure 3 in the above white paper, uses the FPGA clock to determine the time between digital input events. High-Performance Test. 2. NI CompactRIO 디바이스 드라이버. CompactRIO . cRIO-908x Firmware and Additional Drivers는 디바이스 드라이버뿐 아니라 cRIO-9081 및 cRIO-9082 컨트롤러용 펌웨어를 포함합니다. Reference this information to ensure you install the correct version when upgrading or updating your operating system, or when migrating or porting code to a new system. NI GPIBコントローラおよびGPIBポートを備えたNI組込コントローラをサ. When using cRIO in windows, you should actually add the back p. ni-daqmx. CompactRIO . Systems Engineering Software. Supported Operating. Safety Guidelines for Hazardous Locations. RJ-45 Ethernet1 256 MB DDR3 512 MB NAND Flash GigE MAC/PHY Xilinx Zynq-7000 XC7Z020 All-Programmable SoC + + RGMII ONFI NI cRIO-9066. CompactRIO . From troubleshooting technical issues and product recommendations, to quotes and orders, we’re here to help. RT variant is intended to work headless. Dynamic Synchrophasor Estimation Algorithm Using Taylor Weighted Least Square Method With. Learn more about ni crio-9082 Hello Users and Professionals, I am going yo purchase NI cRIO-9082. I would like to use the NI cRIO-9045. Hey André, I owe you an apology. NI FPGAハードウェア (RIO、Rシリーズなど) で使用するLabVIEW FPGAコードをローカルでコンパイルする場合や、コンパイルツールのローカルインストールが必要なLabVIEW FPGAの機能を使用する場合には、正しいバージョンのXilinxコンパイルツールをインストールする必要があります。通常、必要なXilinx. An FPGA-based prototype is developed using NI cRIO 9082 and LabVIEW platform for real-time measurements. LabVIEW. The controllers are configured using SCM 2015. I2C protocol implementation NI cRIO 9082 - NI9401. NI-VISA. Provides support for NI GPIB controllers and NI embedded controllers with GPIB ports. Show lessThe hardware of the control system, installed inside the back of the car in an aluminium structure (see Figure 5a), comprises two 12 V DC batteries to isolate our systems from the car power system, a Compact-Rio 9082 Controller (National Instruments, Austin, TX, USA, NI cRIO 9082, see Figure 5b), a NAV440CA-202 Inertial Measurement Unit. ni gpibコントローラおよびgpibポートを備えたni組込コントローラをサポートします。Use this guide to select the correct display cable for your CompactRIO Controller. EtherCAT용 NI-Industrial Communications. #### #Date: Mon, May 13, 2019 3:17:04 PM #OSName: PharLap ETS 13. This solution is the NI Real-Time Hypervisor, which is a solution that currently only ships with the PXI platform. Project. I have a cRIO 9073 connected to a PC via a crossover cable. cRIO-908x Firmware and Additional Drivers는 디바이스 드라이버뿐 아니라 cRIO-9081 및 cRIO-9082 컨트롤러용 펌웨어를 포함합니다. NI cRIO-9082 用于CompactRIO 的可重配置嵌入式机箱,带集成的智能实时控制器 本文档列出了National Instruments cRIO-9082 的产品规范。除非另外声明,否则下列规 范的适用温度范围均为-40 °C~70 °C 。 警告 请勿尝试采用本文档中未提到的方式操作cRIO-9082。错误操作设备可I'm using a cRIO 9082, with some high speed data acquisition module, like 9224, which is supposed to operate at 1 MHz sampling rate. The specification manuals for NI CompactDAQ (cDAQ) and CompactRIO (cRIO) chassis and controllers provide the technical details necessary to determine or choose which chassis or controller are best suited for your application, and as a reference to validate performance during system development. 本文介绍了如何从 CompactRIO (cRIO) 或 cDAQ 控制器控制 CompactDAQ (cDAQ),以便系统无需 PC 即可运行。. Ethernet 10/100/1000 LAN Connector LED Indications (Continued) LED LED Color LED State Condition *UHHQ 2Q 0ELW VGDWDUDWHVHOHFWHGPerspectives showcases how NI sees what’s next in the world of test and technology. 783832-02. Try using ping to make sure both cRIO and your host computer. Guaranteed | (888) 88-SOURCE | Table 8. Your cRIO-9082 runs Phar Lap ETS on an x86 CPU while your cRIO-9064 runs NI Linux on an ARM CPU. NI-DAQmx. the purpose of the application is to continously aquire and log data to an access database located on another computer located on the network (i do not have any form of office instal. NI는 시스템에 가장 최신 소프트웨어를 사용할 것을 권장합니다. Provides support for NI data acquisition and signal conditioning devices. An update is available for NI CompactRIO 13. Tale regolatore è controllabile mediante protocollo modbus RTU.